Deployed fire suppression/response is not adequate, caused by:
- Immediate reignition of a liquid fuel before it is detected
- Fire or explosion compromises fire suppression system
- Fire suppression design cannot easily extinguish a large vertical fire (in part due to fire suppression system (FSS) capacity and medium not suitable to type of fire and/or inadequate activation delay and inability to target heat source with FSS)
- Reignition because fuel source cannot be isolated and hot surfaces are not cooled
- Reignition because heat source is only temporarily cooled and there is still fuel e.g. electrical fault or engine still running
- Flame location does not allow effective suppression
- Deployment of suppression system does not shut down the machine and heat source and/or ongoing input of fuel to the fire occurs
This Credible Failure mode is addressed by:
- BI-02A.43 Alarms provide verbal directions for operators in fire situations
- BI-02A.46 Fire suppression specification for mobile equipment
- BI-02A.53 Operator display specifications are detailed for mobile equipment
- BI-05.06 Regular monitoring of equipment status that predicts fires, alarms on equipment, and notifies
- BI-09B.02 General Fire Training
- BI-09B.03 Operator Fire Training